Skip to main content
British Association for Cytopathology March 2026 Case Study

Synovial fluid – Aspiration of a joint following total hip replacement

Susan Smith, Reporting Biomedical Scientist, Pathlinks Northern Lincolnshire & Goole Hospitals NHS Trust

  • Female, age 72.
  • Left total hip replacement in 2016
  • Attended A&E after a significant fall
  • Complains of significant clicking of the left hip over the past 12 months
  • X-ray confirmed no dislocation or fracture
  • Clinically no clicking or grating felt or heard during manipulation of the joint
QUIZ